Products
CRI CCC 06-20A — 50 Hz Three-Speed Circulation Pump

CRI CCC 06-20A 50 Hz three-speed catalogue reference with native High, Medium and Low curves, separate speed-specific table limits and qualified dimensional references. Supplied configuration requires confirmation.
CRI CCC 06-20A circulation pump
Three-speed circulation pump catalogue reference within the existing CRI CP range.
This page describes the exact CCC 06-20A three-speed catalogue reference. High, Medium and Low remain separate manufacturer speed references. The selected commercial supply, motor, controls and connection arrangement require confirmation.
| Reference | Manufacturer value |
|---|---|
| Manufacturer model | CCC 06-20A |
| Operation | Three speeds: High / Medium / Low; 50 Hz catalogue |
| Capacitor reference | 3 µF |
| Pipe size | 20 mm |
| Port-to-port reference | 130 mm |
| Inlet / outlet reference | 1¼ inches |
| Catalogue weight reference | 2.3 kg |
Speed-specific manufacturer table limits
| Speed | Power (W) | Current (A) | Maximum head (m) — separate limit | Maximum flow (m³/h) — separate limit |
|---|---|---|---|---|
| H — High | 93 | 0.42 | 6 | 3.3 |
| M — Medium | 67 | 0.3 | 5 | 2.3 |
| L — Low | 46 | 0.21 | 3 | 1.3 |
Model-specific hydraulic curves
Maximum head and maximum flow are separate table limits for each speed; they do not describe one operating duty. The native head traces are reproduced as drawn, independently of the tabulated maxima. No efficiency trace, tabulated duty points, zero-head flow or extrapolated performance is inferred. Confirm the selected duty with the manufacturer.
Model-specific dimensional references
| Reference | Manufacturer value |
|---|---|
| Height H | 130 mm |
| Connection size DN | 20 |
| First printed L (mm) column | 129 mm |
| D reference | 1¼ inches |
| Second printed L (mm) column | 123 mm |
The manufacturer dimensional table prints two separate columns headed L (mm). Their literal values are retained as first and second L references. The drawing labels D1 separately; neither L value is reassigned to D1. Confirm the final dimension-to-drawing mapping and supplied assembly drawing before installation.
The exact performance row specifies a 130 mm port-to-port reference, agreeing with H = 130 mm in the dimensional row. The 1¼ inches inlet/outlet reference does not establish flange drilling or pressure class. No flange-type asterisk is printed for this exact model.
Power and current are speed-specific catalogue references: H 93 W / 0.42 A, M 67 W / 0.3 A, L 46 W / 0.21 A. These do not identify a selected supplied motor, voltage or control package. The 3 µF capacitor and 2.3 kg catalogue weight are not a supplied accessory or packed/shipping-weight claim.
Permissible working pressure, temperature, materials and selected installation require confirmation for quotation. No model-specific working-pressure rating or supplied accessory package is assigned here.
Source: Manufacturer Circulatory Pumps catalogue: physical page 12 / printed page 10 (exact performance rows and head graphs), physical page 9 / printed page 7 (exact dimension row). Source labels and separate maxima are retained.
Return to the CRI CP range · Request a configured-pump quotation