Products

CRI CCC 06-25A — 50 Hz Three-Speed Circulation Pump

CRI CCC 06-25A 50 Hz three-speed catalogue reference with native High, Medium and Low curves, separate speed-specific table limits and qualified dimensional references. Supplied configuration requires confirmation.

CRI CCC 06-25A circulation pump

Three-speed circulation pump catalogue reference within the existing CRI CP range.

This page describes the exact CCC 06-25A three-speed catalogue reference. High, Medium and Low remain separate manufacturer speed references. The selected commercial supply, motor, controls and connection arrangement require confirmation.

ReferenceManufacturer value
Manufacturer modelCCC 06-25A
OperationThree speeds: High / Medium / Low; 50 Hz catalogue
Capacitor reference3 µF
Pipe size25 mm
Port-to-port reference130 mm
Inlet / outlet reference1½ inches
Catalogue weight reference2.4 kg

Speed-specific manufacturer table limits

SpeedPower (W)Current (A)Maximum head (m) — separate limitMaximum flow (m³/h) — separate limit
H — High930.4263.3
M — Medium670.352.3
L — Low460.2131.3

Model-specific hydraulic curves

CRI CCC 06-25A 50 Hz native High Medium and Low head curves
Manufacturer Circulatory Pumps catalogue, physical page 13 / printed page 11. Native head traces only; efficiency excluded.

Maximum head and maximum flow are separate table limits for each speed; they do not describe one operating duty. The native head traces are reproduced as drawn, independently of the tabulated maxima. No efficiency trace, tabulated duty points, zero-head flow or extrapolated performance is inferred. Confirm the selected duty with the manufacturer.

Model-specific dimensional references

ReferenceManufacturer value
Height H130 mm
Connection size DN25
First printed L (mm) column129 mm
D reference1½ inches
Second printed L (mm) column123 mm

The manufacturer dimensional table prints two separate columns headed L (mm). Their literal values are retained as first and second L references. The drawing labels D1 separately; neither L value is reassigned to D1. Confirm the final dimension-to-drawing mapping and supplied assembly drawing before installation.

The exact performance row specifies a 130 mm port-to-port reference, agreeing with H = 130 mm in the dimensional row. The 1½ inches inlet/outlet reference does not establish flange drilling or pressure class. No flange-type asterisk is printed for this exact model.

Power and current are speed-specific catalogue references: H 93 W / 0.42 A, M 67 W / 0.3 A, L 46 W / 0.21 A. These do not identify a selected supplied motor, voltage or control package. The 3 µF capacitor and 2.4 kg catalogue weight are not a supplied accessory or packed/shipping-weight claim.

Permissible working pressure, temperature, materials and selected installation require confirmation for quotation. No model-specific working-pressure rating or supplied accessory package is assigned here.

Source: Manufacturer Circulatory Pumps catalogue: physical page 13 / printed page 11 (exact performance rows and head graphs), physical page 9 / printed page 7 (exact dimension row). Source labels and separate maxima are retained.

Return to the CRI CP range · Request a configured-pump quotation