LEO 32SWPm3.6-30-2.2L/QG Sewage Grinding Pump

2.2 kW 1-phase 50 Hz sewage grinding pump; individual reference curve and exact product dimensions. Source conflicts flagged; supplied duty/version confirmation required.

LEO 32SWPm3.6-30-2.2L/QG sewage grinding pump

Semi-open vortex impeller with cutting/grinding system for pressure sewage transfer. The product photograph is a representative manufacturer image for the 32SWP design family, not a guarantee of the exact supplied motor-stack length or accessories.

Published technical specifications

Power2.2 kW / 3 HP
Phase / frequency / poles1-phase / 50 Hz / 2 poles; voltage requires supplied-nameplate confirmation.
Nominal discharge32 mm (1¼ inch); confirm interface.
Rated duty, published tableQ=3.6 m³/h at H=30 m
Separate maximum flow / head, published table12 m³/h / 30.2 m
Liquid temperature / pH0–40°C / pH 4–10
Cable length reference10 m
Insulation / protectionClass F / IP68
Maximum immersionUnresolved: 5 m manufacturer/European reference versus 10 m local sheet. Do not assume 10 m; confirm supplied instructions.
Float switchNot promised as standard for this version.

Individual hydraulic reference and dimensions

32SWPm3.6-30-2.2L/QG individual reference curve and exact phase-specific dimension table
Approximate readings from the manufacturer graph, rounded to 0.1 m (reading uncertainty about ±0.3 m), not certified test points. Original product outline with this model’s exact dimension row, not packaging.
Approx. flow Q (m³/h)0.1123456789101111.9
Approx. head H (m)30.130.230.230.13029.829.629.328.928.427.826.925.9
L1230 mm
L2191 mm
L396 mm
L4140 mm
H564 mm
H173 mm
D32 mm
D190 mm
D214 mm
M16 mm

Source conflicts and installation checks

The manufacturer graph and technical table disagree on parts of the performance envelope. The chart below reproduces approximate graph readings; the separate rated and maximum values retain the published numerical table without blending the two. Neither is independently confirmed. Request a selection against the actual duty and supplied version before ordering. Maximum flow and maximum head are separate limits, not one duty point. The graph also prints “7” at the evenly spaced 8 m³/h tick; flow calibration uses the consistent axis spacing and l/min scale, not that apparent label error.

No zero-head endpoint or extrapolated performance has been invented. Confirm cable, voltage, phase, operating immersion, duty point, elbow/flange and installation clearances before purchase. The grinding system does not establish a verified solids-passage diameter.

View SWP range · Request a quotation and duty confirmation