Products

LEO 50SWUm9-6-0.55L Submersible Sewage Pump

0.55 kW 1-phase 50 Hz sewage pump; individual hydraulic reference and exact product dimensions. Source discrepancies flagged; supplied duty/version confirmation required.

LEO 50SWUm9-6-0.55L submersible sewage pump

Semi-open vortex impeller for wastewater containing impurities and long-fibre substances. Manufacturer photograph represents the 50SWU design family; exact motor-stack length and supplied accessories may vary.

Published technical specifications

Power0.55 kW / 0.75 HP
Phase / frequency / poles1-phase / 50 Hz / 2 poles; confirm voltage from supplied nameplate.
Nominal discharge50 mm; confirm actual elbow/coupling.
Rated duty, source tableQ=9 m³/h at H=6 m
Separate maximum flow / head, source table19 m³/h / 9.5 m
Maximum solids diameter, source table35 mm
Liquid temperature / pH0–40°C / pH 4–10
Immersion limit5 m European versus 10 m local sheet: unresolved, confirm supplied instructions and do not assume higher limit.
Cable reference10 m
Insulation / protectionClass F / IP68
Float switchListed as standard for single-phase power ≤1.1 kW; confirm package.

Individual hydraulic reference and dimensions

50SWUm9-6-0.55L individual hydraulic reference and phase-specific dimensional drawing/table
Approximate graph-derived reference (about ±0.3 m reading uncertainty), not certified test points. Original manufacturer product outline, exact model/phase dimension row, not packaging.
Approx. Q (m³/h)0.112345678910111213141516171818.6
Approx. H (m)9.59.18.78.37.97.57.16.86.465.65.14.73.93.63.12.521.41
L1195 mm
L2160 mm
L380 mm
L4121 mm
H483 mm
H164 mm
D35 mm
D1110 mm
D214 mm
M14 mm

Source conflicts and installation checks

The graphs and numerical ratings are separate manufacturer references, not independently certified duty data. Maximum flow and maximum head are separate limits, not one operating point. The individual curve uses approximate readings of the original orange stroke (about ±0.3 m reading uncertainty), not a fit through the rated/max table. Dimensions are source table values, not measured installation approval; confirm actual phase-specific height and the elbow/coupling interface. Nominal discharge must not be substituted for the drawing dimension D.

No extrapolated shut-off or zero-head endpoint has been invented. Confirm duty, voltage, operating immersion, actual phase, pipe interfaces and clearances before ordering.

View SWU range · Request a quotation and duty confirmation