Products
LEO 65SWU24-12.5-2.2L Submersible Sewage Pump
2.2 kW 3-phase 50 Hz sewage pump; individual hydraulic reference and exact product dimensions. Source discrepancies flagged; supplied duty/version confirmation required.
LEO 65SWU24-12.5-2.2L submersible sewage pump
Semi-open vortex impeller for wastewater containing impurities and long-fibre substances. Manufacturer photograph represents the 65SWU design family; exact motor-stack length and supplied accessories may vary.
Published technical specifications
| Power | 2.2 kW / 3 HP |
|---|---|
| Phase / frequency / poles | 3-phase / 50 Hz / 2 poles; confirm voltage from supplied nameplate. |
| Nominal discharge | 65 mm; confirm actual elbow/coupling. |
| Rated duty, source table | Q=24 m³/h at H=12.5 m |
| Separate maximum flow / head, source table | 40 m³/h / 17 m |
| Maximum solids diameter, source table | 55 mm |
| Liquid temperature / pH | 0–40°C / pH 4–10 |
| Immersion limit | 5 m European versus 10 m local sheet: unresolved, confirm supplied instructions and do not assume higher limit. |
| Cable reference | 10 m |
| Insulation / protection | Class F / IP68 |
| Float switch | Not promised as standard for this version. |
Individual hydraulic reference and dimensions
| Approx. Q (m³/h) | 0.1 | 2 | 4 | 6 | 8 | 16 | 18 | 20 | 22 | 24 | 36 | 38 | 39.5 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Approx. H (m) | 17.1 | 16.9 | 16.7 | 16.4 | 16.1 | 14.8 | 14.4 | 13.8 | 13.2 | 12.8 | 9.6 | 8.9 | 8.5 |
| L1 | 266 mm |
|---|---|
| L2 | 218 mm |
| L3 | 110 mm |
| L4 | 167 mm |
| H | 590 mm |
| H1 | 91 mm |
| D | 65 mm |
| D1 | 130 mm |
| D2 | 14 mm |
| M | 16 mm |
Source conflicts and installation checks
The graphs and numerical ratings are separate manufacturer references, not independently certified duty data. Maximum flow and maximum head are separate limits, not one operating point. The individual curve uses approximate readings of the original orange stroke (about ±0.3 m reading uncertainty), not a fit through the rated/max table. Near-overlapping source-graph readings at Q=10–14 and 26–34 m³/h are omitted rather than assigned to the wrong curve. Dimensions are source table values, not measured installation approval; confirm actual phase-specific height and the elbow/coupling interface. Nominal discharge must not be substituted for the drawing dimension D.
No extrapolated shut-off or zero-head endpoint has been invented. Confirm duty, voltage, operating immersion, actual phase, pipe interfaces and clearances before ordering.