Products

LEO AC75

0.75 kW three phase clean-water centrifugal pump. Individual hydraulic curve below. Installation dimensions require confirmation. Price and availability by enquiry.

LEO AC75 Centrifugal Pump

For clean-water transfer, irrigation, circulation and pressure boosting. Match the required flow and total dynamic head to this model's curve. Product photograph represents the range; configuration varies by model.

ModelAC75
Motor power0.75 kW
Motor phaseThree phase
Head at zero flow36 m
Last tabulated duty point6 m³/h at 16 m
Suction / discharge1 inch / 1 inch
Pump bodyCast iron with anti-rust treatment
ShaftAISI 304 stainless steel
Maximum liquid temperature60 °C
Insulation / enclosureClass F / IPX4

Motor has copper windings; single-phase versions include thermal protection. The series lists up to 8 m suction lift; achievable lift depends on altitude, water temperature and pipe losses. Confirm supply voltage, frequency and local availability before ordering. Shut-off head is at zero flow and is not a recommended operating duty.

AC75 hydraulic performance

LEO AC75 individual hydraulic curve

Redrawn from LEO's published technical table. Dots show published values; straight lines interpolate. No extrapolation beyond the published points.

AC75 published flow and head values
Flow (m³/h)Head (m)
036
0.635
0.934
1.233.5
1.833
2.432
331
3.629
4.227
4.526
4.823.5
5.420
616

AC75 installation dimensions

The manufacturer sheet does not give a separate dimensional row for AC75. Ask Krächtig to confirm the drawing for the supplied three-phase version before setting out mounting holes or pipework.

View ACm / AC range · Request a quotation