Products
LEO LEJT2 Self-Priming Sewage Pump
Bare shaft-driven sewage pump. Verified 2350 rpm hydraulic reference and model-specific dimensions. Drive, duty, supplied version and availability require confirmation.
LEO LEJT2 self-priming sewage pump
Bare shaft-driven pump for wastewater duties. Select the drive, materials and seals for the actual installation and liquid. The product image is representative of the LEJT family, not a guarantee of the supplied drive assembly.
Verified hydraulic reference at 2350 rpm
This curve joins the exact published numerical points at the stated speed only. It is not a shut-off curve or a complete operating envelope; do not extrapolate. Confirm allowable drive speed, duty point and absorbed power before selection.
| Flow Q (m³/h) | 12.5 | 15 | 17.5 | 20 | 25 | 30 | 35 | 40 | 45 |
|---|---|---|---|---|---|---|---|---|---|
| Head H (m) | 22.3 | 21.9 | 21.5 | 21.1 | 20.3 | 19.4 | 18.6 | 17.8 | 17 |
Model-specific installation dimensions
| Dimension | mm |
|---|---|
| B | 182.6 |
| B1 | 50.8 |
| C | 17.5 |
| E | 44.4 |
| H | 535 |
| H1 | 452.4 |
| H2 | 551.7 |
| H3 | 152.4 |
| H4 | 342.9 |
| L | 627 |
| L1 | 521 |
| L2 | 226 |
| L3 | 90 |
| L4 | 163 |
| L5 | 269 |
| N | 324 |
| N1 | 295.1 |
| d | 28.4 |
| u | 6.4 |
| T | 31.4 |
| d2 | 14 |
Inlet and outlet: DN50; D=165; K=125; 4 × Ø18 mm. Published pump weight: 112 kg.
Selection and source limitations
The range brochure gives a maximum liquid temperature of 85°C and maximum operating pressure of 6 bar; confirm application and material/seal compatibility. PN16 on the flange drawing describes the flange and is not a 16-bar pump pressure rating. Motor power, supply, exact per-model solids capacity and complete drive dimensions require confirmation.
Some other speed rows contain ambiguous decimal printing, and the range-wide speed statement differs from individual table rows. Only the clearly identified 2350 rpm reference above is transcribed here; other speeds are not verified on this page. Installation dimensions must match the supplied version before fabrication.
View the LEJT range · Request a quotation and duty confirmation