Products
LEO LEJT4 Self-Priming Sewage Pump
Bare shaft-driven sewage pump. Verified 1750 rpm hydraulic reference and model-specific dimensions. Drive, duty, supplied version and availability require confirmation.
LEO LEJT4 self-priming sewage pump
Bare shaft-driven pump for wastewater duties. Select the drive, materials and seals for the actual installation and liquid. The product image is representative of the LEJT family, not a guarantee of the supplied drive assembly.
Verified hydraulic reference at 1750 rpm
This curve joins the exact published numerical points at the stated speed only. It is not a shut-off curve or a complete operating envelope; do not extrapolate. Confirm allowable drive speed, duty point and absorbed power before selection.
| Flow Q (m³/h) | 48 | 64 | 80 | 96 | 112 | 128 | 144 | 160 |
|---|---|---|---|---|---|---|---|---|
| Head H (m) | 28.1 | 26.9 | 25.9 | 24.8 | 23.7 | 22.5 | 21 | 19.2 |
Model-specific installation dimensions
| Dimension | mm |
|---|---|
| B | 279.4 |
| B1 | 77.8 |
| C | 25.4 |
| E | 69.8 |
| H | 756 |
| H1 | 654 |
| H2 | 743 |
| H3 | 222.2 |
| H4 | 495.3 |
| L | 814 |
| L1 | 723 |
| L2 | 295 |
| L3 | 127 |
| L4 | 228 |
| L5 | 319 |
| N | 508 |
| N1 | 457.2 |
| d | 38.1 |
| u | 9.6 |
| T | 42.1 |
| d2 | 18 |
Inlet and outlet: DN100; D=220; K=180; 8 × Ø18 mm. Published pump weight: 260 kg.
Selection and source limitations
The range brochure gives a maximum liquid temperature of 85°C and maximum operating pressure of 6 bar; confirm application and material/seal compatibility. PN16 on the flange drawing describes the flange and is not a 16-bar pump pressure rating. Motor power, supply, exact per-model solids capacity and complete drive dimensions require confirmation.
Some other speed rows contain ambiguous decimal printing, and the range-wide speed statement differs from individual table rows. Only the clearly identified 1750 rpm reference above is transcribed here; other speeds are not verified on this page. Installation dimensions must match the supplied version before fabrication.
View the LEJT range · Request a quotation and duty confirmation