Bare shaft-driven sewage pump. Verified 1750 rpm hydraulic reference and model-specific dimensions. Drive, duty, supplied version and availability require confirmation.

LEO LEJT4 self-priming sewage pump

Bare shaft-driven pump for wastewater duties. Select the drive, materials and seals for the actual installation and liquid. The product image is representative of the LEJT family, not a guarantee of the supplied drive assembly.

Verified hydraulic reference at 1750 rpm

This curve joins the exact published numerical points at the stated speed only. It is not a shut-off curve or a complete operating envelope; do not extrapolate. Confirm allowable drive speed, duty point and absorbed power before selection.

LEO LEJT4 head-flow reference curve at 1750 rpm
Selected-speed reference from LEO June 2026 technical data.
Flow Q (m³/h)48648096112128144160
Head H (m)28.126.925.924.823.722.52119.2

Model-specific installation dimensions

LEO LEJT4 dimensional drawing and exact model dimensions
Dimensions in mm; bare pump, not a complete motor/base assembly.
Dimensionmm
B279.4
B177.8
C25.4
E69.8
H756
H1654
H2743
H3222.2
H4495.3
L814
L1723
L2295
L3127
L4228
L5319
N508
N1457.2
d38.1
u9.6
T42.1
d218

Inlet and outlet: DN100; D=220; K=180; 8 × Ø18 mm. Published pump weight: 260 kg.

Selection and source limitations

The range brochure gives a maximum liquid temperature of 85°C and maximum operating pressure of 6 bar; confirm application and material/seal compatibility. PN16 on the flange drawing describes the flange and is not a 16-bar pump pressure rating. Motor power, supply, exact per-model solids capacity and complete drive dimensions require confirmation.

Some other speed rows contain ambiguous decimal printing, and the range-wide speed statement differs from individual table rows. Only the clearly identified 1750 rpm reference above is transcribed here; other speeds are not verified on this page. Installation dimensions must match the supplied version before fabrication.

View the LEJT range · Request a quotation and duty confirmation