Products

LEO EVP2-6 Vertical Multistage Pump

1 kW, 3-phase, 6-stage EVP pump. Individual numerical hydraulic reference and installation dimensions. Confirm supplied revision and duty.

LEO EVP2-6 vertical multistage pump

Vertical multistage centrifugal pump for water supply, pressure boosting, circulation and irrigation. The product photograph represents the EVP design family, not the exact stage height, motor frame or supplied accessories.

Published technical specifications

ModelEVP2-6
Power P2, source row1 kW
Impeller stages6
Supply reference3-phase / 50 Hz; 380–415 V manufacturer standard range; confirm supplied nameplate.
Maximum published head at Q=069 m; not a continuous-duty point
Published numerical flow span0–4 m³/h; no zero-head endpoint inferred
Maximum operating pressure15 bar; confirm total inlet plus pump pressure for actual unit.
Liquid / ambient temperature+5 to +60°C model sheet / maximum ambient +40°C. Higher catalogue temperature is unconfirmed.
Main materialsCast-iron inlet/outlet; AISI 304 jacket; engineering-plastic (PPO) impellers/diffusers; carbon/ceramic seal. Confirm supplied revision.

Individual hydraulic curve and installation dimensions

EVP2-6 exact manufacturer numerical hydraulic points with individual dimensional table and original outline
Individual source-point reference at 50 Hz; exact numerical row, no fitted or extrapolated endpoint. Dimensions are product installation references, not packaging.
Flow Q (m³/h)01234
Head H (m)6965523718

Model-specific dimension table

A478 mm
B218 mm
C193 mm
D110 mm
E202 mm
F114.5 mm
GG1 (inch designation)
HG1 (inch designation)
K166 mm
L140.5 mm

Source qualifications and installation checks

The individual hydraulic reference reproduces the exact numerical manufacturer row at 50 Hz. Straight line segments only connect printed points; they are not measured intermediate points or a certified acceptance curve. No zero-head endpoint, best-efficiency point or operating range has been invented. Maximum head occurs at Q=0 and is not a continuous-duty recommendation. Liquid-temperature sources differ: the model sheets print +5 to +60°C while the full commercial catalogue prints +5 to +75°C. Confirm the supplied pump/seal limit; this page does not promise operation above +60°C. A–F, K and L are millimetres. G/H are source connection designations in inches, not millimetres. Confirm the supplied thread standard and orientation. The manufacturer explicitly prints 1.0 kW for this row; this has not been silently changed to 1.1 kW or converted from the inconsistent HP entry.

Source references: LEO model technical sheet, technical and dimension tables; full LEO commercial pump technical catalogue, EVP section. Checked 16 October 2026. Obtain supplied-revision confirmation for the required duty, liquid temperature, thread interface and installation clearances before ordering.

View EVP range · Request a quotation and duty confirmation