LEO EVPm6-3 Vertical Multistage Pump

1.1 kW, 1-phase, 3-stage EVP pump. Individual numerical hydraulic reference and installation dimensions. Confirm supplied revision and duty.

LEO EVPm6-3 vertical multistage pump

Vertical multistage centrifugal pump for water supply, pressure boosting, circulation and irrigation. The product photograph represents the EVP design family, not the exact stage height, motor frame or supplied accessories.

Published technical specifications

ModelEVPm6-3
Power P2, source row1.1 kW
Impeller stages3
Supply reference1-phase / 50 Hz; 220–240 V manufacturer standard range; confirm supplied nameplate.
Maximum published head at Q=030 m; not a continuous-duty point
Published numerical flow span0–10 m³/h; no zero-head endpoint inferred
Maximum operating pressure15 bar; confirm total inlet plus pump pressure for actual unit.
Liquid / ambient temperature+5 to +60°C model sheet / maximum ambient +40°C. Higher catalogue temperature is unconfirmed.
Main materialsCast-iron inlet/outlet; AISI 304 jacket; engineering-plastic (PPO) impellers/diffusers; carbon/ceramic seal. Confirm supplied revision.

Individual hydraulic curve and installation dimensions

EVPm6-3 exact manufacturer numerical hydraulic points with individual dimensional table and original outline
Individual source-point reference at 50 Hz; exact numerical row, no fitted or extrapolated endpoint. Dimensions are product installation references, not packaging.
Flow Q (m³/h)012345678910
Head H (m)3029.52928.528272624.5232119

Model-specific dimension table

A487 mm
B190 mm
C210 mm
D125 mm
E198.5 mm
F110 mm
GG1¼ (inch designation)
HG1¼ (inch designation)
K166 mm
L140.5 mm

Source qualifications and installation checks

The individual hydraulic reference reproduces the exact numerical manufacturer row at 50 Hz. Straight line segments only connect printed points; they are not measured intermediate points or a certified acceptance curve. No zero-head endpoint, best-efficiency point or operating range has been invented. Maximum head occurs at Q=0 and is not a continuous-duty recommendation. Liquid-temperature sources differ: the model sheets print +5 to +60°C while the full commercial catalogue prints +5 to +75°C. Confirm the supplied pump/seal limit; this page does not promise operation above +60°C. Letters follow the full manufacturer installation drawing. The shorter EVP6 sheet renames the port threads E/F; on this drawing the threads are G/H. E=198.5 mm and F=110 mm are drawing dimensions, not port sizes.

Source references: LEO model technical sheet, technical and dimension tables; full LEO commercial pump technical catalogue, EVP section. Checked 16 October 2026. Obtain supplied-revision confirmation for the required duty, liquid temperature, thread interface and installation clearances before ordering.

View EVP range · Request a quotation and duty confirmation